搜索
Search
Confirm
Cancel

PRODUCTS

All categories

Find products quickly

Welcome to consult now

Telephone consultation:

GDCQ electromagnetic voltage regulating soft start series

02

02

  • Product Description
  • Principles and characteristics
  • Model definition and selection instructions
  • Technical parameter
  • One time plan
  •   Overcome the current technical bottleneck of high-voltage resistance of power electronic devices, and successfully expand the low-voltage soft-starting technology to the field of high-voltage motor soft-starting, and provide users with a high-voltage motor with high cost performance, high control accuracy, high stability and high reliability. Soft start control equipment.

      products are widely used in building materials, metallurgy, mining, petroleum, chemical, electric power, papermaking, water conservancy, municipal administration and other industries.

    • 1

       

        Connect the high-voltage winding of the voltage regulator to the stator winding of the motor in series, and connect the low-voltage winding to the anti-parallel thyristor. According to the principle of the transformer, the terminal voltage of the high-voltage winding Ub1=K×Ub2 (K is the transformation ratio of the transformer). Using computer control technology to continuously adjust the conduction angle of the low-voltage side thyristor according to the starting requirements and control the change of Ub2, the terminal voltage Ub1 of the high-voltage winding can be controlled.

        Motor terminal voltage: Ud=Us-Ur-Ub1

        Us is the power supply voltage, and Ur is the voltage drop of the internal resistance of the power supply.

        When starting, QF is closed first, and KM is disconnected. By controlling the conduction angle of the thyristor, the voltage Ub1 at both ends of the voltage regulator is gradually reduced, so that the voltage Ud at the motor terminal is gradually increased, the motor torque is gradually increased, and the speed is gradually increased. Rise to make the motor start smoothly. After starting, close the KM and put the motor into full-voltage operation.

        By controlling the terminal voltage of the motor, the starting current is actually controlled. When the starting current is 2~3 times the rated current (about 1.5 when necessary), it is much lower than the full voltage starting current (5~7 times the rated current). Rated current). As a result, the voltage drop of the power grid during starting is greatly reduced, and the impact on electrical and mechanical equipment is also greatly reduced.

    •   Please declare separately when ordering with special needs, and it will be adjusted according to user requirements.

        When it is estimated that the current will be more than 3.5 times the rated current, the order should indicate the heavy-duty type.

       

      1

       

        Description:

        1. The control part of the integrated cabinet and the transformer are in one cabinet, including the controller, thyristor components, voltage regulating transformer and short-circuit switch;

        2, the combination cabinet is composed of a control cabinet and a transformer cabinet, and the control cabinet contains a controller, thyristor components and a short-circuit switch;

        3, the split transformer is placed separately outside the cabinet, the control cabinet contains the controller, thyristor components, and the short-circuit switch needs to be equipped with a switch cabinet;

        4. The overall dimensions of the product should be added to the structural dimensions plus the thickness of the front and rear door panels totaling about 50mm, and the thickness of the two ends plus the partitions totaling about 30mm;

        5. The corresponding number of isolation cabinets needs to be increased when one is used for multiple times;

        6. According to different user requirements and configurations, product size and layout can be adjusted according to actual conditions.

        7. When the load is heavy, the estimated starting current is greater than 3.5 times the rated current, please indicate the heavy-duty type when selecting the model.

       

      1

       

        Description:

        1, the control part of the integrated cabinet and the auto-voltage regulator are in one cabinet, including the controller, thyristor components, auto-voltage regulator and bypass switch;

        2, each phase auto-voltage regulator of the split cabinet is a one-sided cabinet, including the controller, thyristor components, and the short-circuit switch needs to be equipped with a switch cabinet;

        3. The overall dimensions of the product should be added to the structural dimensions plus the thickness of the front and rear door panels totaling about 50mm, and the thickness of both ends plus the partitions totaling about 30mm;

        4. The corresponding number of isolation cabinets needs to be increased when using one towing multiple times;

        5. According to user requirements and configurations, product size and layout can be adjusted according to actual conditions.

    •   Start-stop mode: soft start, straight start, soft stop, free stop;

        ◎Control mode: smart, voltage ramp, constant time, sudden jump;

        ◎Operation mode: this cabinet, external control, communication remote control;

        ◎Setting method: 1--LCD screen, 2--background communication;

        ◎Communication: RS485 interface: Modbus communication protocol (default);

        ◎Starting sudden jump: 50%~90%Ue, time 0.5~2 seconds (adjustable);

        ◎Initial voltage: 10%~80%Ue (adjustable);

        ◎Starting current multiple: 1Ie~4Ie (adjustable);

        ◎Start and soft stop time: 1~120S;

        ◎Continuous start interval: 5-15 minutes (if necessary, it can be less than 2 minutes);

        ◎Cooling method: natural cooling; ◎LCD display: parameters such as starting current, starting time and fault information;

        ◎Chinese interface (other languages ​​can be selected by default);

        ◎Main circuit working pressure: 6kV~15kV;

        ◎Operating power supply: AC220V/50Hz 300VA;

        ◎Protection grade: IP32.

        Use environmental conditions

        1. Ambient temperature: -20℃ 45℃;

        2, the relative humidity of the air does not exceed 90%;

        3, the altitude is not more than 2000m; (special design can be used when exceeding)

        4, the inclination of the ground is not more than 5°;

        5. There is no fire, explosion hazard, chemical corrosion and severe vibration at the installation site

        Note: If there are special conditions of use, please indicate when ordering.

    • 1

      1

 GBRQ series frequency conversion soft starter
GBRQ series frequency conversion soft starter
The company introduces and digests the power electronic technology of Emerson Company of the United States, and develops and produces the GBRQ series of high-voltage variable frequency soft starters.
 GSDQ water resistance soft starter series
GSDQ water resistance soft starter series
GSDQ series water resistance soft starters are mainly suitable for starting and protecting devices of three-phase induction squirrel cage asynchronous and synchronous motors with rated working voltages of 3, 6, and 10KV and power range of 200-30000KW.
 GDKQ series high-voltage reactance starting cabinet
GDKQ series high-voltage reactance starting cabinet
GDKQ series high-voltage reactance starting cabinet
 GZDW DC screen
GZDW DC screen
DC screen is the abbreviation of GZDW intelligent electric power operation power system, which is composed of charging screen and battery screen.
 SDQ series water resistance soft starter
SDQ series water resistance soft starter
SDQ series water resistance soft starter is mainly suitable for the soft starter of winding asynchronous motor with three-phase AC 50Hz, rated working voltage of 380V, 3KV, 6KV, 10KV, and rated power of 75KW or more.
 GDCQ electromagnetic voltage regulating soft start series
GDCQ electromagnetic voltage regulating soft start series
Overcome the current technical bottleneck of high-voltage resistance of power electronic devices, and successfully expand the low-voltage soft-starting technology to the field of high-voltage motor soft-starting, and provide users with a high-voltage motor with high cost performance, high control accuracy, high stability and high reliability. Soft start control equipment.
 FZS water loading device
FZS water loading device
Scope of application    is mainly suitable for load test of all kinds of generator sets below 10000kVA
 DGQ series (AC motor) low voltage solid state soft starter
DGQ series (AC motor) low voltage solid state soft starter
DGQ-C series intelligent soft start control device is specially designed for the start and stop of low-voltage asynchronous motors of different powers in various industries.
 VDK series vacuum circuit breaker
VDK series vacuum circuit breaker
Dayu Electric Technology Co., Ltd. is a high-tech enterprise under the National Key Torch Plan, with stock code 430386 on the New Third Board. The company specializes in the research and development, design, and manufacturing of various industrial electrical products such as large and medium-sized motor soft start devices, variable frequency speed regulation energy-saving devices, power system power compensation devices, high and low voltage complete sets of equipment, and electric vacuum devices. It is a manufacturer in the same industry that covers a variety of starting products including pure resistance, power electronic, electromagnetic, and variable frequency soft start. In the field of motor energy-saving control, the company's GBT-MV series high-voltage frequency converter research is synchronized with international top technology, and the brushless doubly fed frequency conversion speed control system has passed the achievement appraisal of Hubei Provincial Department of Science and Technology.

TOP

Dayu Electric Technology Co., Ltd

Share

Copyright: Dayu Electric Technology Co., Ltd      TEL:0712-2883450   Address: No. 2, Hangtian Avenue, Xiaogan, Hubei

Dayu Electric Technology Co., Ltd